ANN-BUS Products

​​​​​​

ANN-80

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red.
The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red.

ANN-80-W (White)

The ANN-80-W annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80-W and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80-W is white.
The ANN-80-W annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80-W and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80-W is white.

ANN-LC

The ANN-LC (Lite-Connect) is a solution that allows building owners reduce the number of phone lines by consolidating the central station communications to a single MS-9050UD fire alarm control panel. Using fiber-optic technology, the panels are connected together and the MS-9050UD sends point or zone information to the Central Station for the entire system. In addition, a building to building connection with fiber-optic cable avoids potential ground fault issues and damage caused by lightning strikes.
<p><a href="https://pages1.honeywell.com/HLS-FLSK-20140731-Form-Lite-Connect_Sales_Contact.html" target="_blank"><img src="http://www.firelite.com/en-US/PublishingImages/but-contact_sales-red.png" width="110" height="38"></a></p>
The ANN-LC (Lite-Connect) is a solution that allows building owners reduce the number of phone lines by consolidating the central station communications to a single MS-9050UD fire alarm control panel. Using fiber-optic technology, the panels are connected together and the MS-9050UD sends point or zone information to the Central Station for the entire system. In addition, a building to building connection with fiber-optic cable avoids potential ground fault issues and damage caused by lightning strikes.

ANN-RLY

The ANN-RLY relay module provides 10 programmable Form- C relays when used with a compatible FACP (Fire Alarm Control Panel). The ANN-RLY module may be mounted inside the FACP main circuit board chassis, ROME or in the battery area of the enclosure using optional mounting bracket.
The ANN-RLY relay module provides 10 programmable Form- C relays when used with a compatible FACP (Fire Alarm Control Panel). The ANN-RLY module may be mounted inside the FACP main circuit board chassis, ROME or in the battery area of the enclosure using optional mounting bracket.

ANN-I/O

The ANN-I/O is an LED driver module that can be used in a wide variety of applications including as an interface with the Fire Alarm Control Panel (FACP) to drive most customized graphic annunciators. It comes in a plastic enclosure that may be mounted inside a custom annunciator or accessory cabinet and can drive up to 40 LEDs.
The ANN-I/O is an LED driver module that can be used in a wide variety of applications including as an interface with the Fire Alarm Control Panel (FACP) to drive most customized graphic annunciators. It comes in a plastic enclosure that may be mounted inside a custom annunciator or accessory cabinet and can drive up to 40 LEDs.

ANN-S/PG

The ANN-S/PG Interface module connects either a serial or parallel printer with a compatible Fire Alarm Control Panel (FACP) to print real-time logs of system events, detector status reports, and event histories. The ANN-S/PG and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. A single four-conductor unshielded cable may be used for both power and data communications.
The ANN-S/PG Interface module connects either a serial or parallel printer with a compatible Fire Alarm Control Panel (FACP) to print real-time logs of system events, detector status reports, and event histories. The ANN-S/PG and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. A single four-conductor unshielded cable may be used for both power and data communications.

ANN-LED

The ANN-LED annunciator module provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel (FACP). The ANN-LED module provides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones or addressable points. ANN-RLED has red LEDs only for alarm communication of up to 30 addressable points.
The ANN-LED annunciator module provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel (FACP). The ANN-LED module provides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones or addressable points. ANN-RLED has red LEDs only for alarm communication of up to 30 addressable points.

ROME

The ROME (Relay Option Module Enclosure) is shipped with one ANN-RLY Module installed. The ANN-RLY Relay Module provides ten programmable  Form-C relays when used with a compatible FACP (Fire Alarm Control Panel) using the ANN-BUS communication circuit. The ROME can be installed remotely up to 1250 feet away from the FACP location, in an Elevator, Electrical or Mechanical room reducing the wiring cost and installation time.
The ROME (Relay Option Module Enclosure) is shipped with one ANN-RLY Module installed. The ANN-RLY Relay Module provides ten programmable Form-C relays when used with a compatible FACP (Fire Alarm Control Panel) using the ANN-BUS communication circuit. The ROME can be installed remotely up to 1250 feet away from the FACP location, in an Elevator, Electrical or Mechanical room reducing the wiring cost and installation time.
SwiftPage
SWIFT Resources
Informative Technical
Sell Sheet Drawings
Overview Video Engineering Spec
Case Study: Vail Ski Championship Tech Bulletins
Value Calculator LED Indications (Gateway)
Product Images LED Indications (Detectors/Modules)
FAQ W-USB Adapter Upgrade Procedure
All SWIFT Firmware
Quick Start Guide SWIFT Tools
Link Test
Mesh Network Videos
RF Scan Technical How-To Series
Technical How-To Series
Archived Webinar SWIFT Wireless 2.0 & Applications
Applications
Tools
Lite Specs