All Products

​​​​​​
​​
SWIFT wireless addressable devices provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a class A mesh network. Great for applications where it is costly, obtrusive, or possibly dangerous to use traditional wired devices. ​

<< 1 2 3 4 5 >>

MMF-300(A) Series and MDF-300 Modules

Four monitor modules are available for Fire-Lite Alarm’s MS-9050UD, MS-9200UDLS, and MS-9600 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors.
Four monitor modules are available for Fire-Lite Alarm’s MS-9050UD, MS-9200UDLS, and MS-9600 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors.

ANN-LC

The ANN-LC (Lite-Connect) is a solution that allows building owners reduce the number of phone lines by consolidating the central station communications to a single MS-9050UD fire alarm control panel. Using fiber-optic technology, the panels are connected together and the MS-9050UD sends point or zone information to the Central Station for the entire system. In addition, a building to building connection with fiber-optic cable avoids potential ground fault issues and damage caused by lightning strikes.
<p><a href="https://pages1.honeywell.com/HLS-FLSK-20140731-Form-Lite-Connect_Sales_Contact.html" target="_blank"><img src="http://www.firelite.com/en-US/PublishingImages/but-contact_sales-red.png" width="110" height="38"></a></p>
The ANN-LC (Lite-Connect) is a solution that allows building owners reduce the number of phone lines by consolidating the central station communications to a single MS-9050UD fire alarm control panel. Using fiber-optic technology, the panels are connected together and the MS-9050UD sends point or zone information to the Central Station for the entire system. In addition, a building to building connection with fiber-optic cable avoids potential ground fault issues and damage caused by lightning strikes.

ECC-50BDA

The ECC-50BDA is an intelligent amplifier that can be configured for 50 watts or 100 watts of total audio power. It is used with the ECC-50/100(E) emergency voice evacuation system to amplify an audio message for distribution throughout a facility when additional power is required. , It provides 50 watts or 100 watts of primary power along with 50 watts of backup power and comes standard with eight built-in, fully supervised speaker circuits/zones. It can be conveniently installed near an area of protection to reduce wiring demands for speaker circuit.
The ECC-50BDA is an intelligent amplifier that can be configured for 50 watts or 100 watts of total audio power. It is used with the ECC-50/100(E) emergency voice evacuation system to amplify an audio message for distribution throughout a facility when additional power is required. , It provides 50 watts or 100 watts of primary power along with 50 watts of backup power and comes standard with eight built-in, fully supervised speaker circuits/zones. It can be conveniently installed near an area of protection to reduce wiring demands for speaker circuit.

W-GATE Wireless Gateway

W-GATE is the wireless fire system gateway that acts as a bridge between the MS-9200UDLS and MS-9600(UD)LS fire alarm control panels (FACPs) and wireless fire devices. The wireless gateway uses mesh technology to communicate with the devices and offers high reliability for commercial applications. The W-GATE can be installed anywhere on the SLC and is an excellent solution retrofits and “hard to wire” applications. The W-GATE requires a W-DIS-D (Wireless Display Driver) and ANN-80-W (ANN-80 Annunciator, White).<div>&nbsp;</div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/DF-60821.pdf" class="productdocanchor">Datasheet</a></div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/LS10036-000FL-E.pdf" class="productdocanchor">Manual</a></div><div class="productdocdivs"><a class="productdocanchor" href="http://www.firelite.com/en-us/Pages/Product.aspx?category=Wireless%20Fire%20Alarm%20Solution&cat=HLS-FIRELITE&pid=W-GATE">Learn more</a></div>
W-GATE is the wireless fire system gateway that acts as a bridge between the MS-9200UDLS and MS-9600(UD)LS fire alarm control panels (FACPs) and wireless fire devices. The wireless gateway uses mesh technology to communicate with the devices and offers high reliability for commercial applications. The W-GATE can be installed anywhere on the SLC and is an excellent solution retrofits and “hard to wire” applications. The W-GATE requires a W-DIS-D (Wireless Display Driver) and ANN-80-W (ANN-80 Annunciator, White).
 

W-DIS-D Wireless Display Driver

W-DIS-D is a Wireless Display Driver that is required to annunciate any wireless-specific events from the system. It receives the event information from the wireless network and then connects to a dedicated ANN-80-W for annunciation. All standard fire alarm events will report on the MS-9200UDLS and MS-9600(UD)LS just like a standard wired device. Any wireless-specific events (such as low battery), will annunciate a general trouble at the FACP and specific information on the ANN-80-W.<div>&nbsp;</div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/DF-60821.pdf" class="productdocanchor">Datasheet</a></div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/LS10036-000FL-E.pdf" class="productdocanchor">Manual</a></div><div class="productdocdivs"><a class="productdocanchor" href="http://www.firelite.com/en-us/Pages/Product.aspx?category=Wireless%20Fire%20Alarm%20Solution&cat=HLS-FIRELITE&pid=W-DIS-D">Learn more</a></div>
W-DIS-D is a Wireless Display Driver that is required to annunciate any wireless-specific events from the system. It receives the event information from the wireless network and then connects to a dedicated ANN-80-W for annunciation. All standard fire alarm events will report on the MS-9200UDLS and MS-9600(UD)LS just like a standard wired device. Any wireless-specific events (such as low battery), will annunciate a general trouble at the FACP and specific information on the ANN-80-W.
 

ANN-80-W Annunciator

ANN-80-W is a compact, backlit, 80-character LCD annunciator that can be used to annunciate wireless-specific events. It connects to the W-DIS-D Wireless Display Driver using a two-wire serial interface employing the ANN-BUS communication format. Two additional wires from the host FACP are required for power. Any wireless-specific events (such as low battery), will annunciate a general trouble at the FACP and specific information on the ANN-80-W.<div>&nbsp;</div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/df-52417.pdf" class="productdocanchor">Datasheet</a></div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/LS10036-000FL-E.pdf" class="productdocanchor">Manual</a></div><div class="productdocdivs"><a class="productdocanchor" href="http://www.firelite.com/en-us/Pages/Product.aspx?category=Wireless%20Fire%20Alarm%20Solution&cat=HLS-FIRELITE&pid=ANN-80-W">Learn more</a></div>
ANN-80-W is a compact, backlit, 80-character LCD annunciator that can be used to annunciate wireless-specific events. It connects to the W-DIS-D Wireless Display Driver using a two-wire serial interface employing the ANN-BUS communication format. Two additional wires from the host FACP are required for power. Any wireless-specific events (such as low battery), will annunciate a general trouble at the FACP and specific information on the ANN-80-W.
 

W-SD355/W-SD355T Wireless Photoelectric Smoke Detectors

W-SD355 and W-SD355T addressable, wireless photoelectric detectors use a state of the art photoelectric sensing chamber to provide open area protection. The W-SD355T adds thermal sensors that will alarm at a fixed temperature of 135⁰F (57⁰C). They are intended for use with the MS-9200UDLS and MS-9600(UD)LS Addressable Fire Alarm Control Panels. The W-SD355 and W-SD355T communicate with the fire alarm control panels through a wireless mesh network to the W-GATE wireless gateway. <div>&nbsp;</div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/DF-60833.pdf" class="productdocanchor">Datasheet</a></div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/I56-4081-000.pdf" class="productdocanchor">Manual</a></div><div class="productdocdivs"><a class="productdocanchor" href="http://www.firelite.com/en-us/Pages/Product.aspx?category=Wireless%20Fire%20Alarm%20Solution&cat=HLS-FIRELITE&pid=W-SD355">Learn more</a></div>
W-SD355 and W-SD355T addressable, wireless photoelectric detectors use a state of the art photoelectric sensing chamber to provide open area protection. The W-SD355T adds thermal sensors that will alarm at a fixed temperature of 135⁰F (57⁰C). They are intended for use with the MS-9200UDLS and MS-9600(UD)LS Addressable Fire Alarm Control Panels. The W-SD355 and W-SD355T communicate with the fire alarm control panels through a wireless mesh network to the W-GATE wireless gateway.
 

W-H355/W-H355R Wireless Heat Detectors

W-H355 and W-H355R addressable, wireless heat detectors use a state-of-the-art thermistor sensing circuit for a fast response. The W-H355 and W-H355R provide fixed temperature alarm detection at 135°F. The W-H355R also provides Rate-of-Rise Detection at 15⁰F/min. These detectors are designed to provide open area protection and are intended for use with the MS-9200UDLS and MS-9600(UD)LS Addressable Fire Alarm Control Panels. The W-H355 and W-H355R communicate with the fire alarm control panels through a wireless mesh network to the W-GATE wireless gateway. <div>&nbsp;</div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/DF-60833.pdf" class="productdocanchor">Datasheet</a></div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/I56-4082-000.pdf" class="productdocanchor">Manual</a></div><div class="productdocdivs"><a class="productdocanchor" href="http://www.firelite.com/en-us/Pages/Product.aspx?category=Wireless%20Fire%20Alarm%20Solution&cat=HLS-FIRELITE&pid=W-H355">Learn more</a></div>
W-H355 and W-H355R addressable, wireless heat detectors use a state-of-the-art thermistor sensing circuit for a fast response. The W-H355 and W-H355R provide fixed temperature alarm detection at 135°F. The W-H355R also provides Rate-of-Rise Detection at 15⁰F/min. These detectors are designed to provide open area protection and are intended for use with the MS-9200UDLS and MS-9600(UD)LS Addressable Fire Alarm Control Panels. The W-H355 and W-H355R communicate with the fire alarm control panels through a wireless mesh network to the W-GATE wireless gateway.
 

W-MMF Wireless Addressable Monitor Module

W-MMF addressable, wireless monitor module is a standard-sized module that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. It can be used for a variety of applications, such as monitoring conventional pull stations. This module is designed to supervise a circuit of dry-contact input devices and are intended for use with the MS-9200UDLS and MS-9600(UD)LS Addressable Fire Alarm Control Panels. The W-MMF communicates with the fire alarm control panels through a wireless mesh network to the W-GATE wireless gateway.<div>&nbsp;</div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/DF-60830.pdf" class="productdocanchor">Datasheet</a></div><div class="productdocdivs"><a href="http://www.firelite.com/CatalogDocuments/I56-4083-000.pdf" class="productdocanchor">Manual</a></div><div class="productdocdivs"><a class="productdocanchor" href="http://www.firelite.com/en-us/Pages/Product.aspx?category=Wireless%20Fire%20Alarm%20Solution&cat=HLS-FIRELITE&pid=W-MMF">Learn more</a></div>
W-MMF addressable, wireless monitor module is a standard-sized module that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. It can be used for a variety of applications, such as monitoring conventional pull stations. This module is designed to supervise a circuit of dry-contact input devices and are intended for use with the MS-9200UDLS and MS-9600(UD)LS Addressable Fire Alarm Control Panels. The W-MMF communicates with the fire alarm control panels through a wireless mesh network to the W-GATE wireless gateway.
 

ISO-6 (A) Fault Isolator Module

ISO-6 Six Fault Isolator ModuleThe ISO-6(A) Six Fault Isolator Module provides six equivalent circuits that will allow a portion of the communications loop to continue operating when a short circuit occurs on that loop. An amber LED indicator will blink in the normal state for each of the six inputs and will latch on during a short circuit condition. The module will automatically restore the communications loop to normal condition when the short circuit is removed.
ISO-6 Six Fault Isolator ModuleThe ISO-6(A) Six Fault Isolator Module provides six equivalent circuits that will allow a portion of the communications loop to continue operating when a short circuit occurs on that loop. An amber LED indicator will blink in the normal state for each of the six inputs and will latch on during a short circuit condition. The module will automatically restore the communications loop to normal condition when the short circuit is removed.

MMF-900 (LA only)

Product only available in Latin America.
Product only available in Latin America.

CMF-900 (LA only)

Product only available in Latin America.
Product only available in Latin America.

MMF-902 (LA only)

Product only available in Latin America.
Product only available in Latin America.

I900 (LA only)

Product only available in Latin America.
Product only available in Latin America.

IO900 (LA only)

Product only available in Latin America.
Product only available in Latin America.

SD992 (LA Only)

Product only available in Latin America.
Product only available in Latin America.

H995 (LA Only)

Product only available in Latin America.
Product only available in Latin America.

B901A (LA Only)

Product only available in Latin America.
Product only available in Latin America.

CP900 (LA Only)

Product only available in Latin America.
Product only available in Latin America.

MCP900 (LA Only)

Product only available in Latin America.
Product only available in Latin America.
SwiftPage
SWIFT Resources
Informative Technical
Sell Sheet Drawings
Overview Video Engineering Spec
Case Study: Vail Ski Championship Tech Bulletins
Value Calculator LED Indications (Gateway)
Product Images LED Indications (Detectors/Modules)
W-USB Adapter Upgrade Procedure
Quick Start Guide All SWIFT Firmware
Link Test SWIFT Tools
Mesh Network
RF Scan Videos
Technical How-To Series
SWIFT Wireless 2.0 & Applications
Archived Webinar
Applications Tools
Lite Specs