1-800-627-3473    |     Free Training    

 

   
 

 

 

Addressable Detectors & Modules

Product
Data Sheet
Description
SD355(A) / SD355T(A) Addressable Photoelectric Smoke Detectors
Fire-Lite's SD355 and SD355T addressable, low-profile plug-in photoelectric detectors use a state of the art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with the MS-9050UD, MS-9200UDLS, and MS-9600 Addressable Fire Alarm Control Panels. The SD355T adds thermal sensors that will alarm at a fixed temperature of 135F (57C).

CP355(A) Intelligent Addressable Ionization Smoke Detectors

Fire-Lite's CP355 addressable, low-profile, plug-in ionization detector uses a state-of-the-art ionization sensing chamber to provide open-area protection and is used exclusively with Fire-Lite’s MS-9050UD, MS-9200UDLS, and MS-9600 addressable Fire Alarm Control Panels. The ionization detector is used to sense products of combustion and report the measured level of such product to the panel.


H355(A) Series Intelligent Addressable Thermal Detectors

Fire-Lite's H355 Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open area protection and are intended for use with Fire-Lite’s MS-9050UD, MS-9200UDLS, and MS-9600 Fire Alarm Control Panels. Both the H355 and H355R provide fixed temperature alarm detection at 135F. H355HT provides fixed-high temperature detection.


AD355(A) “Adapt” Multi-Sensor Low-Profile Intelligent Detectors

Fire-Lite's AD355 Adapt detector is an intelligent, addressable, multi-sensing, low-profile detector designed for use with the addressable fire alarm control panels. The Adapt detector combines photoelectric and thermal sensing technologies designed to increases immunity to false alarms.

 

 


D350PL(A) and D350RPL(A) Intelligent Low-Flow Photoelectric Duct Smoke Detectors

Fire-Lite’s D350PL(A) and D350RPL(A) Intelligent Low-Flow Photoelectric Smoke Duct Detectors provide low-flow technology that enables duct smoke detection throughout a broad range of airflow environments in HVAC applications. The low-flow technology can detect smoke at air speed velocities of 100 feet per minute or greater, while continuing the same reliable performance to 4,000 feet per minute.


BEAM355 and BEAM355S
Fire-Lite's BEAM355 and BEAM355S are intelligent, addressable projected beam smoke detectors for protecting open areas with high and sloping ceilings, and wide-open areas, where spot-type smoke detectors are difficult to install and maintain.

MMF-300-10(A) Ten-Input Monitor Module
Fire-Lite's MMF-300-10(A) ten-input monitor module provides an interface between the MS-9050UD, MS-9200UDLS, and MS-9600 and normally open contact devices such as pull stations, security contacts or flow switches. Provisions are included for disabling a maximum of two unused addresses.

MMF-302-6 Six Zone Interface Module

Fire-Lite’s MMF-302-6 six-zone interface module provides an interface between all Fire-Lite addressable panels and a two-wire conventional detection zone. A common SLC input is used for all modules, and the initiating device circuits share a common external supervisory supply and ground.


CMF-300-6 Six-Circuit Supervised Control Module

Fire-Lite's CMF-300-6 six-circuit supervised control module provides the MS-9050UD, MS-9200UDLS and MS-9600 with supervised monitoring of wiring to load devices that require an external power supply to operate, such as horns, strobes or bells. Each module is intended for switching applications involving AC, DC, and audio which require wiring supervision.


CRF-300-6 Six-Relay Control Module
Fire-Lite’s CRF-300-6 six-relay control module provides an intelligent alarm system with six Form-C relays. Provisions are included for disabling a maximum of three unused modules.

I300(A) Fault Isolator Module

Fire-Lite's I300(A) Fault Isolator Module is used with the MS-9050UD, MS-9200UDLS, and MS-9600 to protect the system against wire-to-wire short circuits on the SLC loop. The I300(A) should be placed between each device on the SLC loop, to isolate a short-circuit problem between the modules. It is required for true Style 7 operation so that other devices can continue to operate normally in the event of a short-circuit on the SLC.


MMF-300(A) Series and MDF-300 Addressable Monitor Modules

Four monitor modules are available for Fire-Lite Alarm’s MS-9050UD, MS-9200UDLS, and MS-9600 intelligent fire alarm control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors.


CMF and CRF Series Addressable Control and Relay Modules
DF-52130
Fire-Lite's CMF-300 Addressable Control Module provides a supervised Class B (Style Y) or Class A (Style Z) circuit for Notification Appliances (horns, strobes, etc.) Addressability allows the CMF to be activated, either manually or through panel programming, on a select basis. The CRF-300 Relay Module provides two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door holders, control equipment, etc.
 

 

 

 

 

 

 

 

Find a local sales office or convenient distributor near you.

 

 

Related Information:

System Sensor