Conventional Detectors


Product
Data Sheet
Description

I 3 Series

 

The System Sensor I 3 Series detectors are designed on three principles: Installation ease, Intelligence, and Instant inspection. The I 3 Series detectors automatically adjust their sensitivity settings based on dust accumulation in their chamber, resulting in an increased resistance to false alarms.

The I 3 Series detectors are capable of generating a remote maintenance signal when they are in need of cleaning. The design of these detectors emphasizes ease of installation and field maintenance.


1151 & 2151

 

The System Sensor 1151 and 2151 are low-profile ionization and photoelectric, plug-in type smoke detector heads. They offer superb performance and reliability, meeting the stringent performance criteria designated by UL 268 and ULC, in a profile of just 1.66" (42mm). Aesthetically pleasing to engineers, architects, building owners and homeowners, the 1151 and 2151 can be used with four different adapter bases in a variety of wiring configurations and voltages. Model 1151 (ionization sensor) and 2151 (photoelectric sensor) share the same sleek low-profile design.


1451

 

The System Sensor 400 Series plug-in ionization smoke detectors respond quickly to both fast flaming and slow smoldering fires as required by UL 268. Unipolar dual chamber sensor has the sensitivity needed to quickly detect smoke, and the stability needed to avoid false alarms.


DH100P

 

The System Sensor DH100P two-wire duct smoke detector is available as a photoelectronic model. This new design allows for simplified cleaning and maintenance, or a change in application without removing the duct housing. The DH100 samples air currents passing through a duct and gives dependable performance for management of fans, blowers, and air-conditioning systems, preventing the spread of toxic smoke and fire gases through the protected area.


DH100ACDC

 

The System Sensor DH100ACDC four-wire duct smoke detectors are available as wither an ionization or a photoelectronic model. This new design allows for simplified cleaning and maintenance, or a change in application without removing the duct housing. The DH100ACDC samples air currents passing through a duct and gives dependable performance for management of fans, blowers, and air-conditioning systems, preventing the spread of toxic smoke and fire gases through the protected area.


5600

 

System Sensor's 5600 (A) Series mechanical heat detectors offers a low-cost option for property protection against fire and non-life-safety installations, where smoke detectors are inappropriate. Both single and dual circuit models are offered, each available for low and high temperature ratings with either fixed temperature or combination fixed temperature/rate of rise (ROR) activation.  


Beam 1224

 

The System Sensor BEAM1224 and BEAM1224S are four-wire conventional projected beam smoke detectors.
They are uniquely suited for protecting open areas with
high ceilings where spot-type smoke detectors are difficult
to install and maintain. BEAM1224 and BEAM1224S
are to be used with UL Listed compatible fire alarm control
panels only. Installation of the single-ended reflective
design is much quicker than a dual-ended projected beam
detector. Alignment is easily accomplished with an optical
sight and a two-digit signal strength meter incorporated
into the beam detector. Listed for operation from –
22°F to 131°F, the BEAM1224 and BEAM1224S can be
used in open area applications to provide early warning in
environments where temperature extremes exceed the
design limits fo other types of smoke detection.

 

 

 