All Products

​​​​​​​​​​​​​​​​
SWIFT wireless addressable devices provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a class A ​mesh network. Great for applications where it is costly, obtrusive, or possibly dangerous to use traditional wired devices.​​

​​​​​​​​
<< 1 2 3 4 >>

MIZ - Mini-Horn

Wheelock’s MIZ Series Piezoelectric Mini-Horns are compact electronic alarm signals that are listed under UL 464 for Audible Appliances for use in public mode Fire Protection Systems. They are ideal for alarm signaling in individual rooms, apartments, hotels, motels, offices – where attractive appearance, dependable performance and economical installation are prime concerns.
Wheelock’s MIZ Series Piezoelectric Mini-Horns are compact electronic alarm signals that are listed under UL 464 for Audible Appliances for use in public mode Fire Protection Systems. They are ideal for alarm signaling in individual rooms, apartments, hotels, motels, offices – where attractive appearance, dependable performance and economical installation are prime concerns.

MMF-302-6 Interface Module

Fire-Lite’s MMF-302-6 six-zone interface module provides an interface between all Fire-Lite addressable panels and a two-wire conventional detection zone. A common SLC input is used for all modules, and the initiating device circuits share a common external supervisory supply and ground.
Fire-Lite’s MMF-302-6 six-zone interface module provides an interface between all Fire-Lite addressable panels and a two-wire conventional detection zone. A common SLC input is used for all modules, and the initiating device circuits share a common external supervisory supply and ground.

MMF-300-10(A) Monitor Module

Fire-Lite's MMF-300-10(A) ten-input monitor module provides an interface between the MS-9050UD, MS-9200UDLS, and MS-9600(UD)LS and normally open contact devices such as pull stations, security contacts or flow switches. Provisions are included for disabling a maximum of two unused addresses.
Fire-Lite's MMF-300-10(A) ten-input monitor module provides an interface between the MS-9050UD, MS-9200UDLS, and MS-9600(UD)LS and normally open contact devices such as pull stations, security contacts or flow switches. Provisions are included for disabling a maximum of two unused addresses.

MS-10UD

MS-10UD-7 is a ten zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-10UD-7 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The ten zones panel has a built-in Digital Alarm Communicator Transmitter (DACT) and availability to add optional equipment: Remote annunciator, Relay module, LED Driver module, Transmitter module and Printer interface module.
MS-10UD-7 is a ten zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-10UD-7 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The ten zones panel has a built-in Digital Alarm Communicator Transmitter (DACT) and availability to add optional equipment: Remote annunciator, Relay module, LED Driver module, Transmitter module and Printer interface module.

MS-2

MS-2 is a two zone conventional fire alarm control panel compatible with the new I3 smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.
MS-2 is a two zone conventional fire alarm control panel compatible with the new I3 smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.

MS-4

MS-4 is a four zone conventional fire alarm control panel compatible with the new I3 smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.
MS-4 is a four zone conventional fire alarm control panel compatible with the new I3 smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.

MS-5UD

MS-5UD-3 is a five zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-5UD-3 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The five zones panel has a built-in Digital Alarm Communicator Transmitter (DACT) and availability to add optional equipment: Remote annunciator, Relay module, LED Driver module, Transmitter module and Printer interface module.
MS-5UD-3 is a five zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-5UD-3 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The five zones panel has a built-in Digital Alarm Communicator Transmitter (DACT) and availability to add optional equipment: Remote annunciator, Relay module, LED Driver module, Transmitter module and Printer interface module.

MS-9050UD

MS-9050UD is a 50-point addressable fire alarm control panel ideal for smaller facilities such as apartment complexes, banks, cinemas, child care and elementary schools, department stores, food stores, places of worship, restaurants, small retail outlet stores, and other facilities requiring performance-based, sophisticated technology at reasonable cost.
MS-9050UD is a 50-point addressable fire alarm control panel ideal for smaller facilities such as apartment complexes, banks, cinemas, child care and elementary schools, department stores, food stores, places of worship, restaurants, small retail outlet stores, and other facilities requiring performance-based, sophisticated technology at reasonable cost.

MS-9200UDLS

MS-9200UDLS (Rev 3) is a 198-point addressable fire alarm control panel and Digital Alarm Communicator/Transmitter all on one circuit board. This latest version of the MS-9200UDLS includes removable terminal blocks, 2.0A of auxillary power, connection for second ANN BUS, synchronization of up to 16 NAC power supplies and improved protection against electronic shock damage.
MS-9200UDLS (Rev 3) is a 198-point addressable fire alarm control panel and Digital Alarm Communicator/Transmitter all on one circuit board. This latest version of the MS-9200UDLS includes removable terminal blocks, 2.0A of auxillary power, connection for second ANN BUS, synchronization of up to 16 NAC power supplies and improved protection against electronic shock damage.

MS-9600LS/MS-9600UDLS

MS-9600LS is a 318-point addressable fire alarm control panel with optional Digital Alarm Communicator/Transmitter (DACT-UD2) and expandable to 636 addressable points with an optional second Signaling Line Circuit (SLC-2LS).
MS-9600LS is a 318-point addressable fire alarm control panel with optional Digital Alarm Communicator/Transmitter (DACT-UD2) and expandable to 636 addressable points with an optional second Signaling Line Circuit (SLC-2LS).

MRP-2001

MRP-2001 is a six zone releasing fire control panel for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.
MRP-2001 is a six zone releasing fire control panel for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.

MRP-2002

MRP-2002 is a six-zone releasing fire control panel for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.
MRP-2002 is a six-zone releasing fire control panel for single and dual hazard agent releasing applications. The MRP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.

NS Series - Horns & Strobes

The Wheelock Series NS Horn Strobe Appliances will satisfy virtually all requirements for indoor, wall mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or Wheelock’s patented multi-candela strobe with field selectable candela settings of 15/30/75/110cd.
The Wheelock Series NS Horn Strobe Appliances will satisfy virtually all requirements for indoor, wall mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or Wheelock’s patented multi-candela strobe with field selectable candela settings of 15/30/75/110cd.

ROME

The ROME (Relay Option Module Enclosure) is shipped with one ANN-RLY Module installed. The ANN-RLY Relay Module provides ten programmable  Form-C relays when used with a compatible FACP (Fire Alarm Control Panel) using the ANN-BUS communication circuit. The ROME can be installed remotely up to 1250 feet away from the FACP location, in an Elevator, Electrical or Mechanical room reducing the wiring cost and installation time.
The ROME (Relay Option Module Enclosure) is shipped with one ANN-RLY Module installed. The ANN-RLY Relay Module provides ten programmable Form-C relays when used with a compatible FACP (Fire Alarm Control Panel) using the ANN-BUS communication circuit. The ROME can be installed remotely up to 1250 feet away from the FACP location, in an Elevator, Electrical or Mechanical room reducing the wiring cost and installation time.

RSS/RSSP - Strobe Appliances and Strobe Plates

Wheelock’s patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount appliances.
Wheelock’s patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount appliances.

VisorAlarm Plus

The VisorALARM PLUS IP receiver is Teldat’s solution to manage and receive alarms from burglar and/or fire alarm panels equipped with Honeywell Power’s MIP or Fire-Lite Alarm’s IPDACT modules. Each receiver supports up to 3,000 alarm panels and provides the industry’s most advanced set of features including line supervision, 512 bit encryption and a three level redundancy system for the highest possible availability and reliability levels.
The VisorALARM PLUS IP receiver is Teldat’s solution to manage and receive alarms from burglar and/or fire alarm panels equipped with Honeywell Power’s MIP or Fire-Lite Alarm’s IPDACT modules. Each receiver supports up to 3,000 alarm panels and provides the industry’s most advanced set of features including line supervision, 512 bit encryption and a three level redundancy system for the highest possible availability and reliability levels.

XAL-53

The KILLARK® XAL-53 explosion proof pull stations are suitable for use in hazardous areas due to the presence of flammable gases or vapors, combustible dust or easily ignitable fibers. Typical applications for this product include petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled and stored.
The KILLARK® XAL-53 explosion proof pull stations are suitable for use in hazardous areas due to the presence of flammable gases or vapors, combustible dust or easily ignitable fibers. Typical applications for this product include petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled and stored.
SwiftPage
SWIFT Resources
Informative Technical
Sell Sheet Drawings
Overview Video Engineering Spec
Case Study: Vail Ski Championship Tech Bulletins
Value Calculator LED Indications (Gateway)
Product Images LED Indications (Detectors/Modules)
FAQ W-USB Adapter Upgrade Procedure
Quick Start Guide SWIFT Tools
Link Test
Mesh Network Videos
RF Scan Technical How-To Series
Archived Webinar SWIFT Wireless 2.0 & Applications
Applications
Tools
Lite Specs